NPSH available vs required compares what the suction system provides with what the pump manufacturer specifies at a given operating point. NPSH available (NPSHA) comes from the suction conditions. NPSH required (NPSHR) comes from manufacturer data. Compare them at the same flow and speed, using the same head units, then confirm the margin your application needs.
Which inputs affect NPSH available?
For a simple tank feeding a pump, evaluate absolute pressure above the liquid, the liquid elevation relative to the manufacturer’s pump reference datum, suction-line losses and vapour pressure at the operating temperature. Convert each term into head of the pumped liquid. Check minimum liquid level, maximum operating temperature and the relevant suction-flow combination. A restriction or shared suction header can change the result when an additional pump starts.
NPSHR and NPSH3 on a pump curve
NPSH3 refers to the suction head at which the pump’s total head, or first-stage head for a multistage pump, drops by 3% under test. The ANSI/HI guideline for NPSH margin describes the use of manufacturer-supplied NPSHR for margin determination and distinguishes it from tested NPSH3. If a curve only shows NPSH3, confirm with the manufacturer how to use it for your application. The Hydraulic Institute pump FAQs explain the information typically plotted on pump curves.
Worked example: what does a 1.2 m difference mean?
If your system model gives 5.8 m of NPSHA and the manufacturer supplies 4.6 m of NPSHR at the same flow and speed, the arithmetic difference is 1.2 m. That difference alone cannot establish that the selection is suitable. Check the application guidance and the manufacturer’s recommendation, then repeat the comparison for the operating cases that could reduce the margin.
What to record in pump selection software
- Flow, speed, impeller diameter and the manufacturer’s curve revision.
- Liquid temperature, vapour pressure, suction pressure basis and level assumptions.
- Estimated suction losses, per-pump flow and the manufacturer’s specified margin criteria.
- The operating condition with the smallest margin and who reviewed the result.